Problem solve Get help with specific problems with your technologies, process and projects.

Store system info with backups

Following this tip, you will have a backup that includes all of your critical system parameters and values.

The first thing to do before doing a system save is have your CL program issue a command 'PRTSYSINF' and copy the spool file(*LAST) to a data file. You will then have a backup that will include all of your critical system parameters and values. This is especially critical for disaster recovery.


PGM                                      
           
 DCLF  FILE(OUTQPF)               
             MONMSG     MSGID(CPF0000 CPF9999)     
             CHGJOB     OUTQ(QGPL/SYSOUTQ)         
                                                   
/*  PRINT SYSTEM INFORMATION 'IBM' COMMAND       */
             PRTSYSINF                             
CPYSPLF    FILE(QPRTSPLQ) TOFILE(OUTQPF) JOB(*)
             SPLNBR(*LAST) TOMBR(PRTSYS)                       ENDPGM           

==================================