Scott Ingvaldson EXPERT RESPONSE FROM: Scott Ingvaldson

Pose a Question
Other iSeries 400 Categories
Meet all iSeries 400 Experts
Become an Expert for this site


Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


>
QUESTION POSED ON: 07 September 2005
I use the WRKENVVAR to set the variable CLASSPATH. The issue is that the CLASSPATH has already been filled up. How can I increase the length of the Value Field?

>
I had to call SupportLine for the answer to this one: According to the ADDENVVAR documentation the VALUE parameter supports a maximum of 1024 characters; however, the VALUE blank in the ADDENVVAR and CHGENVVAR commands is only 512 characters long!

What SupportLine said was:

This apparently cannot be done from a command line, it looks like you have to use a CL

program:
 ADDENVVAR ENVVAR('CLASSPATH') +                                             
             VALUE('aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa+               
             aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa+               
             aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa+               
             aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa+               
             aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa+               
             aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa+               
             aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa+               
             aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa+               
             aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa+               
             aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa+               
             aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa+               
             aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa+               
             aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa+               
             aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa+               
             aaaaaaaaaaaaaaaaaa')   

The '+' is required, at which point it should allow you to put in an additional line an unlimited number of times -- up to 1024 characters.

Compile the CL program and call it from a command line. The environment variable will be added, and you can view it using WRKENVVAR. To change it, you will need to update your CL program and run it again.

If your classpath needs to be longer than 1024 characters, you may need to put the classpath in a file and set an environment variable to point to the classpath file. Methods for this will vary somewhat depending on your environment.

==================================
MORE INFORMATION ON THIS TOPIC
==================================

The Best Web Links: Tips, tutorials and more.

Visit the ITKnowledge Exchange and get answers to your systems management questions fast.

Read this Search400.com Featured Topic: Take control of your iSeries.

Ask the Experts yourself: Our systems management gurus are waiting to answer your technical questions.


Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   



RELATED CONTENT
iSeries Systems Management
Transfer files from one environment to another without closing all other AS/400 sessions
Send a *LMSG successfully on AS/400 using the SNDDST command
Extend storage capacity on an IBM i without negatively effecting system performance
Configure the iSeries v5r4 to open the HTTPS port for incoming connections
Changing system CCSID
Changing user password expiration
Detecting system changes made by outside IP address
HIPER PTF installation and cover letters for SF99097
Library QUSRSYS not completely installed
SQL statement history storage

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary



Search and Browse the Expert Answer Center
Search and browse more than 25,000 question and answer pairs from more than 250 TechTarget industry experts.
Browse our Expert Advice



iSeries Networking - Printing, Remote Access, TCP/IP
HomeNewsTopicsITKnowledge ExchangeTipsBlogsAsk the ExpertsMultimediaWhite PapersProducts
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides technology professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective purchase decisions and managing their organizations' technology projects - with its network of technology-specific websites, events and online magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Site Map




All Rights Reserved, Copyright 1999 - 2009, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts